Skip to main content

Enforcement Order EPD-HW-1930

Facility Brasseler USA MFG Inc
County Chatham County
Cause of Order Failure to conduct and document weekly inspection of the Central Accumulation Area; failure to make arrangements with local authorities, including emergency responders; failure to include an evacuation plan as part of the Contingency Plan; failure to maintain a Quick Reference Guide as part of the facility's Contingency Plan; failure to label 1 55-gallon drum within the Oakite 33 Satellite Accumulation Area with an indication of the hazards of the contents
Requirements of Order Submit documentation that the facility has addressed violations; submit documentation that the facility is operating in compliance with the requirements for exemption from a permit for a Large Quantity Generator of hazardous waste
Settlement Amount $8,700.00
Legal Authority Hazardous Waste Management Act
Date Executed 7‑Sep‑2021
Publication Date For Executed Order 13‑Sep‑2021
File Attachments None